Arrhenius equation calculator

This Arrhenius equation calculator relates a rate constant to temperature and activation energy. Fill in three of k, A, Ea and T to get the fourth, or enter rate constants measured at two temperatures to get the activation energy directly.

Calculated in your browser. Nothing you type is sent or stored.

Arrhenius equation calculatorOr describe it in Studio →

Fill in three and leave the one you want empty. k and A share the same unit. Large numbers can be typed as 1e13.

Rate constant k

0.7254

k
0.7254
A
1.000e13
Ea
75 kJ/mol
T
298.15 K
Ea ÷ RT
30.25
Ea per molecule
1.245e-19 J = 0.7773 eV
3.26-5.012.963.871000 / T (K⁻¹)ln k
Arrhenius plot, ±40 °C around your temperature. Slope = −Ea/R = -9020 K.

To report

k = 1.000e13 × exp(−75 kJ/mol ÷ (R × 298.15 K)) = 0.7254

Check your result: put the answer back into the equation. 1 × 10¹³ × e^(−30.255) gives the worked example’s 0.725 s⁻¹ again, and on the Arrhenius plot the slope of ln k against 1/T is −Ea ÷ R, here −75,000 ÷ 8.31446 = −9,020 K.
k for the worked example at 25 °C
0.725 s⁻¹
k for the worked example at 25 °C
Ea ÷ RT in that example (30.255 unrounded)
30.25
Ea ÷ RT in that example (30.255 unrounded)
Ea when k doubles from 25 to 35 °C
52.9 kJ/mol
Ea when k doubles from 25 to 35 °C
J/(mol·K), the SI gas constant to six figures
8.31446
J/(mol·K), the SI gas constant to six figures
  • Solves k, A, Ea or T
  • Ea from two temperatures
  • kJ/mol and °C inputs
  • Shows Ea ÷ RT and Ea per molecule (J, eV)
  • Arrhenius plot of ln k against 1/T
  • Runs in your browser, free

01

Arrhenius equation

k = A × e^(−Ea ÷ RT)

ln(k₂ ÷ k₁) = (Ea ÷ R) × (1 ÷ T₁ − 1 ÷ T₂)

k is the rate constant, A the pre-exponential (frequency) factor in the same unit as k, Ea the activation energy in J/mol, R = 8.314 J/(mol·K) and T the temperature in kelvin. The calculator takes Ea in kJ/mol and T in °C and converts.

02

Worked example

A = 1 × 10¹³ s⁻¹, Ea = 75 kJ/mol, T = 25 °C (298.15 K).

Ea ÷ RT = 75000 ÷ (8.31446 × 298.15) = 30.255

k = 1 × 10¹³ × e^(−30.255) = 0.725 s⁻¹

Two-point case: a rate constant that doubles from 0.001 to 0.002 between 25 °C and 35 °C corresponds to Ea = 52.9 kJ/mol.

03

The Arrhenius plot

Taking logs gives a straight line: ln k = ln A − (Ea ÷ R) × (1 ÷ T). Plot ln k against 1/T in kelvin; the slope is −Ea ÷ R and the intercept is ln A. With more than two temperatures, fit that line rather than using two points. The linear regression calculator does it once you have converted the data.

04

Common mistakes with the Arrhenius equation

  • Using degrees Celsius when working it by hand. With T = 25 instead of 298.15 K, the worked example gives k = 2 × 10⁻¹⁴⁴ s⁻¹ instead of 0.725 s⁻¹.
  • Mixing J and kJ when working it by hand. 75 J/mol instead of 75 kJ/mol makes the exponent almost zero, so k comes out as 9.7 × 10¹² s⁻¹, nearly equal to A.
  • Using log₁₀ in the two-point formula, which needs the natural log. A rate that doubles between 25 and 35 °C then gives Ea = 23.0 kJ/mol instead of 52.9 kJ/mol, 2.303 times too small.
  • Assuming every rate doubles for each 10 °C. That holds only near Ea = 52.9 kJ/mol; with the worked example’s 75 kJ/mol, k rises 2.67-fold between 25 and 35 °C.

Trust

How this page is checked

  • The calculation runs on code with automated tests against worked reference values. Every number in the examples on this page was produced by that same code, not typed by hand.
  • The formulas and conventions used are stated on the page, so you can reproduce the result yourself or compare it with your own software.
  • Last reviewed by the Sciloom team, Zebra Nine Studio Inc. It is a tool for research and teaching, not a substitute for a statistician, a validated lab method or medical advice.

Cite this page

Sciloom. (2026). Arrhenius equation calculator. Zebra Nine Studio Inc. https://sciloom.si/arrhenius-equation-calculator

Read the full methodology · Who makes Sciloom

Frequently asked questions

What units does activation energy need?

J/mol when R is 8.314 J/(mol·K). Values are usually quoted in kJ/mol, so multiply by 1,000 first. This calculator does the conversion.

Does a 10 °C rise always double the rate?

No. That rule of thumb holds near room temperature only for an activation energy of about 50 kJ/mol. Higher activation energies respond more strongly to temperature.

What is the pre-exponential factor?

A is the rate constant the reaction would have with no energy barrier. It reflects how often molecules collide in the right orientation, and it has the same unit as k.

Why must temperature be in kelvin?

The equation uses absolute temperature. Using °C gives a wrong answer, and a meaningless one at 0 °C.

Following a first-order decay? The half-life calculator converts between k and half-life.
Free to start, no sign-up.
Back to the tool ↑

More research tools