01
What a PRISMA flow diagram shows
A PRISMA flow diagram reports how a systematic review went from everything its searches found to the studies it finally included. Readers and peer reviewers use it to judge whether the search and screening were complete and reproducible, so most journals ask for one with any systematic review or meta-analysis.
The current version comes from the PRISMA 2020 statement (Page MJ, et al. BMJ 2021;372:n71, doi:10.1136/bmj.n71), which replaced PRISMA 2009. The diagram has three stages:
- Identification: records found in databases and registers, and records removed before screening (duplicates, records marked ineligible by automation tools, and records removed for other reasons).
- Screening: records screened and excluded, reports sought for retrieval and not retrieved, and reports assessed for eligibility with the reasons each excluded report was dropped.
- Included: studies included in the review and the reports of those studies.
Every box label in this generator follows the wording of the official templates on the PRISMA statement website, which are licensed CC BY 4.0.
02
Which of the four PRISMA 2020 templates you need
PRISMA publishes four versions of the flow diagram. Choose with two questions:
| Searched databases and registers only | Also used other methods | |
|---|---|---|
| New review | New review · databases and registers only | New review · databases, registers and other sources |
| Update of a previous review | Updated review · databases and registers only | Updated review · databases, registers and other sources |
- Other methods means anything outside a database or register search: websites, organisations, citation searching (backward or forward), or contacting authors. These get their own column, because records found this way usually go straight to retrieval without title and abstract screening.
- Updated review adds a “Previous studies” column for the studies and reports already included in the earlier version, and a final box with the totals. The generator adds the totals for you.
03
Records, reports and studies: the three counts people mix up
PRISMA 2020 uses three different units, and mixing them up is the easiest way to make a diagram that does not add up.
| Term | Means | Example |
|---|---|---|
| Record | A title and abstract indexed in a database or register | One PubMed entry |
| Report | A document that gives information about a study: a full-text article, preprint, thesis, trial register entry, conference abstract | The full text of a trial publication |
| Study | The investigation itself, which may have several reports | One trial with a main paper and a 5-year follow-up paper |
Screening counts records. Retrieval and eligibility count reports. The last box counts both studies and reports, which is why “studies included” can be smaller than “reports of included studies” but never larger. The generator warns you if it is.
04
How to fill in the PRISMA flow diagram, box by box
- Records identified. Enter the totals from databases and from registers. If you can, list each database with its own count; PRISMA recommends this, and the generator prints the list inside the box.
- Records removed before screening. Duplicates removed by your reference manager or screening tool, records excluded by automation tools, and anything removed for other reasons before anyone screened them.
- Records screened and excluded. Screened is identified minus removed; leave it blank and the generator works it out. Excluded is how many you dropped at title and abstract stage.
- Reports sought and not retrieved. Full texts you tried to get, and those you could not obtain.
- Reports assessed and excluded with reasons. Add one line per reason with its count. Reviewers expect reasons that are specific (“wrong comparator”, not “not relevant”).
- Included. Studies included in the review and the reports of those studies. For updated reviews, the totals with the previous version are added automatically.
05
PRISMA flow diagram examples
Three worked examples drawn by this generator: a meta-analysis that also used citation searching, an update of an earlier review, and a scoping review. The numbers are invented but add up, so you can see how each template behaves. Load one into the generator and replace the counts with yours.
06
PRISMA 2020 vs the PRISMA 2009 flow diagram
Journals now expect the 2020 version. If you are updating a protocol or a review that used the 2009 diagram, these are the changes that affect your counts:
| PRISMA 2009 | PRISMA 2020 | |
|---|---|---|
| Sources | Databases, plus “additional records through other sources” | Databases and registers in one column; other methods in their own column |
| Units counted | Records and full-text articles | Records, then reports, then studies |
| Before screening | Records after duplicates removed | Duplicates, records marked ineligible by automation tools, and records removed for other reasons |
| Retrieval | Not shown | Reports sought for retrieval and reports not retrieved |
| Updated reviews | No separate template | Templates with a “Previous studies” column and totals |
| Synthesis | Studies in qualitative and quantitative synthesis | Studies included in review and reports of included studies |
07
Why the numbers are checked as you type
Numbers that do not add up are easy for a peer reviewer to spot and awkward to explain later. The generator checks the arithmetic that PRISMA implies:
- records screened = records identified − records removed before screening
- reports sought = records screened − records excluded
- reports assessed = reports sought − reports not retrieved
- reports of included studies = reports assessed − reports excluded (in every column)
- studies included ≤ reports of included studies
Blank boxes that can be calculated are filled in and shown in green. A number you typed that disagrees is flagged with the figures that disagree, but never blocked: there are legitimate reasons, such as one report covering two studies, and you can explain them in your methods.
08
Exporting the diagram for a journal
- PowerPoint gives native boxes, text and connector lines on a slide sized to the diagram, so co-authors can edit it without Sciloom. Most journals accept figures saved from Office files.
- PDF is vector, sized to the diagram, with live text you can search and select. Use it when a journal asks for PDF or line art.
- SVG keeps everything as vector with live text. Open it in Illustrator, Inkscape or Affinity to save as EPS if your journal asks for it.
- PNG at 1×, 2× or 3× size, with 300 or 600 dpi written into the file. Choose 600 dpi for line art; many journals ask for higher resolution for diagrams than for photos.
Before you download, step 2 lets you move boxes, reword labels (for example, to name your screening tool), recolour the banners and phase bars, or remove the footnotes. A typical caption reads: “Figure 1. PRISMA 2020 flow diagram of study selection. Adapted from Page MJ, et al. BMJ 2021;372:n71.”
09
PRISMA flow diagram generators compared
We read the public pages of the main free options on 20 November 2026:
| Templates | Downloads | Sign-up and watermark | Checks counts | |
|---|---|---|---|---|
| Sciloom | All four | SVG, PDF, PNG (300 or 600 dpi), PowerPoint, Word, CSV: all free | None, no watermark | Yes, fills blanks |
| ConceptViz | All four | SVG and PNG free; PowerPoint, vector PDF and 600 dpi in a paid pack | No watermark on SVG/PNG; sign-in for the pack | Yes |
| FigCanvas | Any, generated from a text prompt | Free: PNG only; SVG and PDF on paid plans | Free PNG carries a watermark | Not stated |
| Official PRISMA templates | All four | Word (.docx) to fill by hand | None | No |
| PRISMA2020 Shiny app | Options for previous studies and other sources | PDF, PNG, SVG, interactive HTML | None | Not stated |
| Explore Labs | New reviews only | PNG, SVG | None | Yes |
| revisia | All four | PDF, SVG, PNG, Word, CSV | Free account for watermark-free files | Yes |
For the manuscript, download Word: the diagram as a 300 dpi picture on an A4 page with a “Figure 1.” line. For co-authors who will edit boxes and labels, download PowerPoint. Sciloom does not yet import CSV from the PRISMA2020 R package.
Trust
How this page is checked
- The formulas and conventions used are stated on the page, so you can reproduce the result yourself or compare it with your own software.
- Last reviewed by the Sciloom team, Zebra Nine Studio Inc. It is a tool for research and teaching, not a substitute for a statistician, a validated lab method or medical advice.
Cite this page
Sciloom. (2026). PRISMA flow diagram generator. Zebra Nine Studio Inc. https://sciloom.si/prisma-flow-diagram-generator
Frequently asked questions
Is this PRISMA flow diagram generator free?
Yes. All four templates, the checks, the editor and every download format are free, with no account and no watermark.
Does it use the official PRISMA 2020 wording?
Yes. Box labels follow the four official PRISMA 2020 flow diagram templates (Page MJ, et al. BMJ 2021;372:n71), which are licensed CC BY 4.0. A source line is included under the diagram and can be removed.
What is the difference between PRISMA 2009 and PRISMA 2020 flow diagrams?
PRISMA 2020 separates records from reports, adds registers alongside databases, adds a box for records marked ineligible by automation tools, adds a column for other search methods, and has separate templates for updated reviews.
What counts as “other methods” in a PRISMA flow diagram?
Anything that is not a database or register search: websites, organisations, citation searching, hand-searching or contacting study authors. Use one of the “other sources” templates if you used any of them.
Why can studies included be fewer than reports included?
One study can have several reports, such as a main paper, a follow-up paper and a trial register entry. PRISMA asks you to count both. Studies can never exceed reports.
Can I edit the PRISMA diagram in Word or PowerPoint?
For editing, download PowerPoint: every box, label and connector is a native shape you can change in PowerPoint, Keynote or Google Slides. To place the finished diagram in a manuscript, download Word: it holds the diagram as a 300 dpi picture with a “Figure 1.” line, so change the numbers here and download again rather than editing the picture.
Do I need a PRISMA flow diagram for a scoping review?
Scoping reviews follow the PRISMA-ScR extension, which recommends reporting the selection of sources of evidence, ideally with a flow diagram. Many authors use the PRISMA 2020 layout for it; check your journal’s instructions.
Where do I put the PRISMA flow diagram in my paper?
In the results, usually as Figure 1, at the start of the section that describes study selection. Mention it in the methods where you describe screening.